OCIEngine

NDIR | Non-dispersive Infrared Spectroscopy | Gas Sensor

A gas sensor using a patented miniaturized NDIR sepctroscopy technology. It provides quick and constant measurement to high levels of concentrations. It offers high selectivity and few interference. This technology allows the sensor to be very robust. The exposure to gases does not wear out or deteriorate the sensor.

This sensor is specific to analyze a particular gas among those:

Measurement method

Infrared radiation passes through the sensor’s measuring chamber. When air is introduced, the molecules of interest absorb part of the radiation, reducing the intensity of the optical signal. This measurement is then used to calculate the concentration of a specific gas following the Beer-Lambert law:

concentration = log10 (Intensity IR / Intensity zero IR) / Optical Length

  • Dimensions: 21 x 21 x 80 mm
  • Weight: 17 g
  • Fast response time (100ms)
  • High Selectivity
  • Miniaturized footprint (60mm length)
  • Start time < 30 s
  • Avoid calibration
  • Sensitivity
  • Reliability

[PDF] Download the OCIEngine gas sensor datasheet

Calibration

  • Can be calibrated in dry and wet gas
  • Test gas condition: 34°C / >95% HR

Environnemental condition

  • Operating conditions: From 0°C to 55°C
  • Storage: From -10°C to 70°C

Electrical characteristics

  • Supply voltage: 3,7 VDC min, 4,2 VDC max
  • Input current: 1,5A max
  • Communication interface: RS232 protocol, Voltage level: ±5,5V, 3 wires mode
  • Recommended cable sections for all I/O: ≤ 0.13 mm² (AWG ≥ 26)

Technical specifications by gases

Ethanol measurement

  • Measurement range: From 50 to 4000 µg/L
  • Measurement accuracy (max error):
    ○ ± 20 µg/L @ 100 µg/L
    ○ ± 40 µg/L @ 400 µg/L
  • Sampling period: 125 ms
  • Alcohol in mouth detection: Detection above 250 µg/L

See applications:
Exhaled air analysis  –  Agrifood industry

Ethylene measurement

  • Measurement range: From 50 to 4000 µg/L
  • Measurement accuracy (max error):
    ○ ± 20 µg/L @ 100 µg/L
    ○ ± 40 µg/L @ 400 µg/L
  • Sampling period: 125 ms

See applications:
 Agrifood industry

CO2 measurement

  • Measurement range: From 50 to 4000 µg/L
  • Measurement accuracy (max error):
    ○ ± 20 µg/L @ 100 µg/L
    ○ ± 40 µg/L @ 400 µg/L
  • Sampling period: 125 ms

See applications:
Exhaled air analysis  –  Agrifood industry

Acetone measurement

  • Measurement range: From 50 to 4000 µg/L
  • Measurement accuracy (max error):
    ○ ± 20 µg/L @ 100 µg/L
    ○ ± 40 µg/L @ 400 µg/L
  • Sampling period: 125 ms

See applications:
Exhaled air analysis